E271-2201 PC-Bus Controller 21
None (SmartSet Mode) not installed (shipped setting)
E271-141 installed
8- and 12-Bit Modes
When E271-141 emulation mode is enabled, J11 selects whether 8-Bit or 12-Bit
Mode is emulated.
Mode J11
8-Bit installed
12-Bit not installed
The 12-Bit Mode offers greater resolution. 8-bit coordinates are simply 12-bit
coordinates shifted right four bits. Elo driver software internally shifts 8-bit
coordinates left four bits. This way, new calibration points are not required when
switching between 8- and 12-Bit Modes. Calibration is discussed in Chapter 4.
In 8-Bit Mode, a single two-byte transfer is required to read both the X and Y
coordinates. In Interrupt Mode, a single interrupt must be serviced for each
coordinate pair.
In 12-Bit Mode, two separate two-byte transfers are required to read the X and Y
coordinates. In Polled Mode, each polling results in one two-byte transfer. Two
pollings are required for each coordinate pair, one for X and one for Y. In
Interrupt Mode, two interrupts must be serviced for each coordinate pair.
Reserved Jumpers
Jumper J6 on the E271-2201 controller is reserved. It should not be installed.