Elo TouchSystems E221 Manual Página 88

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 87
C-93
Environmental
Temperature/Humidity
Temperature
Operating
-10°C to 50°CNote: Functionality is not adversely affected within
Storage
40°C to 71°C these operating guidelines.
Relative Humidity
Functional operating limits: 90% RH at max 35°C
Functional storage limits
90% RH at max 35°C for 240 hrs, noncondensing
Thermal Cycling
The touchscreen shall be capable of functioning normally after the completion
of fifty thermal cycles from room conditions to 70° C, back to room
temperature; and then to -40° C and back to room temperature at a rate not to
exceed 2º C per minute and with a one hour soak at each temperature extreme.
Immersion
The touchscreen shall be capable of functioning normally after having its lower
edge immersed in water containing 5% isopropyl alcohol to a height one third of
the overall height of the touchscreen, for a period of six hours.
Water Spray
The touchscreen shall function normally and not be damaged by running water
applied to the active area.
Vista de página 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 106 107

Comentários a estes Manuais

Sem comentários